Getting Started
- Plug your Ethernet cable into the OT Range board
- Your laptop gets an IP automatically (10.0.1.x)
- Open a terminal and start scanning:
nmap -sT 10.0.1.0/24
- Find the web server. Open it. Hack your way in.
Challenges
10 progressive challenges. 4700 total points. The scoreboard updates automatically.
| # | Challenge | Points | Guide |
|---|---|---|---|
| 1 | Perimeter Breach | 100 | Start here |
| 2 | Intelligence Gathering | 200 | Hints |
| 3 | Pivot to OT | 300 | Hints |
| 4 | Building Recon | 350 | Hints |
| 5 | Deep Protocol: DNP3 | 400 | Hints |
| 6 | Silent Overpressure | 450 | Hints |
| 7 | Power Blackout | 500 | Hints |
| 8 | Process Manipulation | 600 | Hints |
| 9 | Safety Assault | 800 | Hints |
| 10 | Full Compromise | 1000 | Hints |
Network Map
Five network zones based on the IEC 62443 Purdue Model:
| Zone | Subnet | What’s Inside |
|---|---|---|
| Corporate | 10.0.1.0/24 | Web portal, building management |
| DMZ | 10.0.2.0/24 | Historian, OPC-UA gateway, jump host |
| SCADA | 10.0.3.0/24 | HMI, engineering workstation |
| Process | 10.0.4.0/24 | PLCs: Modbus, DNP3, EtherNet/IP, IEC 104 |
| Safety | 10.0.5.0/24 | Safety Instrumented System |
Protocol Tools
Six custom tools are pre-installed on your Kali machine:
python3 ~/tools/bacnet-tool.py -h # BACnet/IP (Building Automation)
python3 ~/tools/dnp3-tool.py -h # DNP3 (Power/Water SCADA)
python3 ~/tools/enip-tool.py -h # EtherNet/IP (Rockwell PLCs)
python3 ~/tools/iec104-tool.py -h # IEC 104 (Power Grid)
python3 ~/tools/modbus-tool.py -h # Modbus TCP (Chemical Dosing)
python3 ~/tools/s7comm-tool.py -h # S7comm (Siemens Safety)
Each tool uses the same format:
python3 ~/tools/<tool> -t <target-ip> -c <command>
Common commands: scan, read, write
Kali Setup
If tools aren’t installed yet:
cd kali-setup
sudo bash kali-setup.sh
This installs: nmap, sshpass, opcua-client, pymodbus, python-snap7, c104, cpppo, and all 6 protocol tools.
Protocols You’ll Encounter
| Protocol | Port | Real-World Use |
|---|---|---|
| HTTP | 80 | Corporate web systems |
| OPC-UA | 4840 | Industrial data exchange |
| BACnet/IP | 47808 (UDP) | HVAC, lighting, door locks |
| DNP3 | 20000 | Power grids, water utilities |
| EtherNet/IP | 44818 | Factory automation (Rockwell) |
| IEC 104 | 2404 | European power grid SCADA |
| Modbus TCP | 502 | PLCs, chemical dosing |
| S7comm | 102 | Siemens safety controllers |
Tips
- Default nmap only scans top 1000 TCP ports. Industrial protocols use non-standard ports. Scan specifically.
- Not everything is TCP. Some protocols use UDP.
- SSH tunneling is your friend for reaching isolated networks.
- Watch the SCADA HMI. Your attacks have visual impact.
- The scoreboard display shows hints after 15, 30, and 45 minutes.
Plug in. Hack the plant. Learn ICS security.